Amiodarone

Test Code
AMIODAR


Quest Code
36721


CPT Codes
80151 <br><strong>This test is not available for New York patient testing. For New York patient testing use test code 13632</strong>

Includes
Amiodarone and Desethylamiodarone


Preferred Specimen
3 mL serum collected in a red-top tube (no gel)


Minimum Volume
1 mL


Other Acceptable Specimens
Plasma collected in: EDTA (lavender-top) tube, sodium heparin (green-top) tube, or lithium heparin (green-top) tube


Instructions
Centrifuge and immediately separate serum or plasma specimen from the cells into a clean transport tube. Do not use gel barrier/serum separator tube (SST).


Transport Temperature
Frozen


Specimen Stability
Room temperature: 48 hours
Refrigerated: 4 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis • Lipemia • Gel barrier/serum separator tube (SST)


Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Tues, Thurs, Sat; Report available: 3-5 days


Reference Range
1.5-2.5 mcg/mL


Clinical Significance
Amiodarone is an antiarrythmic drug. Therapeutic drug monitoring is useful to monitor compliance and avoid toxicity.


Performing Laboratory
MedFusion
2501 South State Highway 121
Suite 1100
Lewisville, TX 75067-8188



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.