Microsatellite Instability (MSI)

Message
Lab only order code


Test Code
AP MSI


Quest Code
14989


CPT Codes
81301 (ZB0WA)

Preferred Specimen
Formalin-fixed, paraffin-embedded tissue collected in a paraffin block bag


Minimum Volume
Formalin-fixed, paraffin-embedded tissue collected in a paraffin block bag


Other Acceptable Specimens
0.03 mL extracted DNA collected in a sterile, leak-proof container


Instructions
Tissue: One formalin-fixed, paraffin-embedded tissue with representative Tumor. Pathology report is required.

Extracted DNA: Extracted DNA from CLIA-certified laboratory submitted in a sterile leak-proof container. DNA is to be shipped frozen. Do not thaw. Minimum and absolute minimum volume is 0.03 mL. Ship DNA immediately after extraction is performed. DNA must remain frozen until testing.


Transport Temperature
Room temperature


Specimen Stability
Formalin-fixed paraffin block:
Room temperature: Indefinite
Refrigerated: Indefinite
Frozen: Unacceptable


Methodology
Capillary Electrophoresis • Polymerase Chain Reaction (PCR)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
A.M. Sets up 2 days a week.


Report Available
Reports in 3 to 4 days.


Reference Range
See Laboratory Report


Clinical Significance
Patients with early onset and family history of colon cancers are suggestive of hereditary nonpolyposis colon cancer (hnpcc) syndrome. Microsatellite instability analysis on tumor tissue is recommended as a screening test to identify individuals eligible for germline mutation analysis or mismatch repair genes. Microsatellite instability analysis can also be used to identify adult and pediatric patients with unrespectable or metastatic solid tumors who have failed frontline therapy and who would be candidates for targeted immune therapy with Keytruda (Pembrolizumab).


Performing Laboratory
Quest Diagnostics Nichols Institute
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.