Molybdenum

Message
Quest Diagnostics test code: 6213


Test Code
Z1634


Alias/See Also
3000448


CPT Codes
83018

Preferred Specimen
2 mL serum collected in a no additive, trace metal-free (royal blue-top) tube


Minimum Volume
0.6 mL serum or plasma


Other Acceptable Specimens
Plasma collected in a trace metal-free (royal blue-top) tube


Instructions
Promptly centrifuge and separate serum or plasma into an acid-washed plastic screw-capped vial using approved guidelines.


Transport Temperature
Refrigerated


Specimen Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)

Gray top tube (Sodium Fluoride/Potassium Oxalate) • Polymer gel separation tube (serum separator tube or PST)


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

Setup Schedule
As needed


Report Available
8 days


Reference Range
See Patient Report for Reference Range and/or Interpretation of Results


Clinical Significance
Exposure monitoring/investigation.


Performing Laboratory
National Medical Services 200 Welsh Rd Horsham, PA 19044



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.