A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Pneumocystis jirovecii DNA, Qualitative Real-Time PCR
Test Code18835
CPT Codes
87594
Preferred Specimen
1 mL bronchoalveolar lavage, bronchial wash or sputum or
3 mm3 of tissue in a sterile leak-proof container
3 mm3 of tissue in a sterile leak-proof container
Minimum Volume
0.5 mL • 3 mm3
Transport Container
Plastic sterile leak-proof container
Transport Temperature
Refrigerated (cold packs)
Specimen Stability
Room temperature: 24 hours
Refrigerated: 7 days
Frozen: 30 days
Refrigerated: 7 days
Frozen: 30 days
Methodology
Real-Time Polymerase Chain Reaction (PCR)
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Setup Schedule
Set up: Mon-Sat; Report available: 2-3 days
Reference Range
Not detected
Clinical Significance
Detection of Pneumocystis jirovecii DNA by Real-Time PCR is a useful tool for the rapid diagnosis of Pneumocystis pneumonia.
Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA |
33608 Ortega Highway |
San Juan Capistrano, CA 92675-2042 |