Influenza A and B Virus with Subtyping, Real-Time PCR

Test Code
91335


CPT Codes
87502, 87503 (x3)

Includes
Influenza A RNA, QL PCR
Influenza B RNA, QL PCR
Influenza A H3
Influenza A H3N2V
2009 H1N1 Influenza RNA


Preferred Specimen
Nasal or nasopharyngeal swab submitted in 3 mL M4 media or VCM medium (green-cap) tube, or UTM equivalent


Minimum Volume
0.6 mL


Other Acceptable Specimens
3 mL nasopharyngeal aspirate collected in a sterile, leak-proof container


Instructions
Swabs in VCM, M4 or UTM transport media: Use only sterile Dacron or Rayon swabs. Do not use calcium alginate swabs, as they may contain substances that inhibit PCR testing. Break applicator stick off near the tip to permit tightening of the cap.

Nasopharyngeal aspirate: Submit in a sterile container with a leak-proof cap.


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Calcium alginate swabs


Methodology
Real-Time Polymerase Chain Reaction • Real-Time Reverse Transcriptase Polymerase Chain Reaction (RT-PCR)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat; Report available: 2-3 days


Reference Range
Influenza A RNA, QL PCRNot detected
Influenza B RNA, QL PCRNot detected
Influenza A H3Not detected
Influenza A H3N2VNot detected
2009 H1n1 Influenza RNANot detected


Clinical Significance
This test is used to determine the presence of Influenza A or B viral RNA in a patient's specimen, and to differentiate among possible Influenza A virus subtypes.


Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.