Ashkenazi Jewish Panel (4 Tests)

Test Code
90994


CPT Codes
81200, 81220, 81255, 81260

Includes
Cystic Fibrosis, Tay-Sachs DNA, Canavan Disease, Familial Dysautonomia


Preferred Specimen
5 mL whole blood collected in an EDTA (lavender-top) tube


Minimum Volume
3 mL


Other Acceptable Specimens
Whole blood collected in: EDTA (royal blue-top), or ACD solution A or B (yellow-top), or sodium or lithium heparin (green-top) tube


Instructions
CF Method: PCR and Allelic discrimination using an oligonucleotide-ligation (OLA) assay.

Whole blood: Normal phlebotomy procedure. Specimen stability is crucial. Store and ship at room temperature immediately. Do not freeze.


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 8 days
Refrigerated: 8 days
Frozen: Unacceptable


Methodology
Multiplex PCR • Massively Parallel Sequencing • Polymerase Chain Reaction (PCR) • Next Generation Sequencing

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon, Sat; Report Available: 11-17 days


Reference Range
See Laboratory Report


Clinical Significance
This panel consists of the diseases frequent in the Ashkenazi Jewish population that have been recommended for population based carrier screening by the Americal College of Obstetricians and Gynecologists (ACOG) and the American College of Medical Genetics. This panel screens for Cystic Fibrosis, Tay-Sachs (DNA), Canavan Disease, and Familial Dysautonomia.


Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.