Heparin Anti-Xa

Test Code
30292


CPT Codes
85520

Preferred Specimen
2 mL frozen platelet-poor plasma collected in 3.2% sodium citrate (light blue-top) tube


Minimum Volume
1 mL


Instructions
Platelet Poor Plasma: Centrifuge light blue-top tube 15 minutes at approx. 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.


Transport Container

Plastic screw-cap vial



Transport Temperature
Frozen


Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis • Received room temperature • Received refrigerated


Methodology
Chromogenic Assay

Setup Schedule
Set up: Mon-Sat; Report available: Next day


Reference Range
UFH Therapeutic Range 0.30-0.70 IU/mL

LMWH Therapeutic Ranges (target anti-Xa levels measured 4 hours after dosing):
Enoxaparin (Lovenox)  
  Therapeutic bid dosing 0.6-1.0 IU/mL
  Therapeutic qD dosing >1.0 IU/mL
Tinzaparin (Innohep)  
  Therapeutic qD 0.85 IU/mL
Dalteparin (Fragmin)  
  Therapeutic qD 1.05 IU/mL

For more information on this test, go to: http://education.questdiagnostics.com/faq/FAQ53v1 (This link is being provided for informational/ educational purposes only.)


Clinical Significance
This assay is useful in measuring heparin concentration in patients treated with low molecular weight heparins (i.e. Enoxaparin/Lovenox) or unfractionated heparin. It is not intended for measurement of Rivaroxaban (Xarelto) or Fondaparinux (Arixtra).
Refer to test code 90981 for Rivaroxaban measurement and test code 16103 for Fondaparinux measurement.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.