ACREMONIUM KILIENSE (M202) IGE

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
ACRKE


CPT Codes
86003

Preferred Specimen
1 mL serum


Minimum Volume
0.3 mL


Instructions
SST or Red top: Avoid hemolysis. Invert a minimum of 5 times, then allow to clot in an upright position for 30 minutes. Centrifuge the tube for at least 10 minutes. Keep tightly stoppered.


Transport Container
SST (speckled top), Red top, Plastic Vial (transfer) tube


Transport Temperature
Refrigerated (preferred)


Specimen Stability
Room Temperature: n/a
Refrigerated: 7 days
Frozen: at least 7 days


Methodology
Fluorenzyme Immunoassay (FEIA)

Setup Schedule
Monday – Friday
BS


Report Available
1-3 days


Reference Range
 
 
 
 
 
 
 
 
 
Specific IgE Class
 
 
 
 
 
 
 
 
 
kU/L
 
 
 
 
 
 
 
 
 
Specific IgE Antibody
0 < 0.10 Absent/Undetectable
0/1 0.10 - 0.34 Very Low Level
1 0.35 - 0.70 Low Level
2 0.71 - 3.50 Moderate Level
3 3.51 - .17.5 High Level
4 17.6 - 50 Very High Level
5 51.0 - 100 Very High Level
6 > 100 Very High Level 


Clinical Significance
Detection of IgE antibodies specific to a particular allergen indicates hypersensitivity to that allergen.


Performing Laboratory
CompuNet Clinical laboratories, LLC
2308 Sandridge Drive
Moraine, Ohio 45439



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.