EBV Quantitative PCR

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.

This test was developed and its performance characteristics determined by CompuNet Clinical Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration (FDA). The FDA has determined that such clearance or approval is not necessary this test is used for clinical purposes. It should not be considered as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high-complexity testing.


Test Code
EBVDNA


Alias/See Also
74790;
Transplant EBV QPCR;
Transplant EBV DNA Quant;
Epstein Barr Virus DNA, QN RT PCR;
Epstein Barr Virus Quant;
EBV Quant


CPT Codes
87799

Preferred Specimen
2 mL K2EDTA Plasma (Lavender top) tube(s)


Minimum Volume
0.5 mL Plasma
0.5 mL Whole Blood


Instructions
Centrifuge the tube for at least 10 minutes. Transfer plasma to a completely labeled plastic transport tube within 6 hours of collection. Freeze plasma pour off.


Transport Container
K2EDTA (lavender top) tube; Sterile Plastic pour off tube


Transport Temperature
Plasma - Frozen or refrigerated
Whole Blood - Refrigerated


Specimen Stability
Plasma
      Room Temperature = unacceptable
      Refrigerated = 8 hours (24 hours after frist thaw)
      Frozen = 5 days
Whole Blood
     Room Temperature = 8 hours
     Refrigerated = 5 days
     Frozen = unacceptable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Plasma received at room temperature, Whole Blood received frozen.


Methodology
This test employs a Real Time Polymerase Chain Reaction (PCR) for the amplification of a well conserved region of EBV LMP2A Gene.

Setup Schedule
Monday - Wednesday - Friday


Report Available
48 - 72 hours


Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439


Last Updated: August 4, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.