FISH, Multiple Myeloma, IGH/MAFB, t(14;20)

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
IGHM


CPT Codes
88275, 88271 (x2)<br /> **Please note: Test is restricted to bone marrow specimens for New York patient testing**

Preferred Specimen
3 mL bone marrow submitted in culture transport media


Minimum Volume
1 mL


Other Acceptable Specimens
Bone marrow collected in: Sodium heparin (green-top) tube, sodium heparin (royal blue-top) tube, or sodium heparin lead-free (tan-top) tube


Instructions
Specimen viabilitty decreases during transit. Send specimen to testing lab for viability determination. Do not freeze. Do not reject.


Transport Temperature
Room temperature


Specimen Stability
Room temperature: See Collection Instructions
Refrigerated: See Collection Instructions
Frozen: See Collection Instructions


Methodology
Fluorescence in situ Hybridization (FISH)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Daily; Report available: 6 days


Reference Range
See Laboratory Report


Clinical Significance
The IGH-MAFB probe set is used to detect the t(14;20)(q32;q12) in patients with high-risk plasma cell myeloma (PCM).
This translocation is strongly associated with del(13q), hypodiploidy, and gain of 1q. However, patients with t(14;20) and monoclonal gammopathy, MGUS, or smoldering PCM, may have stable disease for years before progressing.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153


Last Updated: November 29, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.