Nickel, Serum/Plasma

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
NICKS


CPT Codes
83885

Preferred Specimen
2 mL Serum or Plasma, See Instructions


Minimum Volume
0.6 mL Serum or Plasma


Instructions
Serum: Collect sample in Royal Blue top tube (Trace metal-free; No additive)
Plasma: Collect sample in Royal Blue top tube (Trace metal-free; K2EDTA)
Promptly centrifuge and separate Serum or Plasma into an acid washed plastic screw capped vial.


Transport Container
Plastic container (Acid washed or Trace metal-free)


Transport Temperature
Refrigerated


Specimen Stability
Room Temperature: 30 days
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gray top tube (Sodium Fluoride / Potassium Oxalate). Lavender top tube (K2EDTA). Polymer gel separation tube (SST or PST).


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

Setup Schedule
Varies


Report Available
4 days


Clinical Significance
Exposure Monitoring/Investigation


Performing Laboratory
NMS Labs
3701 Welsh Road
Willow Grove, PA 19090-2910


Last Updated: August 4, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.