A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Platelet Mapping ADP/AA
MessageMust be drawn at MVH Berry Lab or MVH Main Building 2nd Floor, CompuNet Lab. Samples are limited to 2 hour stability.
Can also be drawn at Atrium Medical Center PSC location, CompuNet Lab. Samples are limited to 2 hour stability.
Test Code
PLTMAP
Alias/See Also
76816;
TEG Platelet Mapping
TEG Platelet Mapping
CPT Codes
85576 x 4
Preferred Specimen
Discard tube required
1- 4.0 mL completely- filled Sodium Heparin (Dark Green Top) or Lithium Heparin non-gel (Light Green Top) tube
NOTE: ONLY 4.0 mL Green top tube may be submitted for testing
1- 4.0 mL completely- filled Sodium Heparin (Dark Green Top) or Lithium Heparin non-gel (Light Green Top) tube
NOTE: ONLY 4.0 mL Green top tube may be submitted for testing
Minimum Volume
4.0 mL
Instructions
Use standard venipuncture and disposal techniques.
Use 21 gauge needle
Collect the required discard tube and completely- filled 4.0 mL sodium or lithium heparin green top tube. GEL tubes are NOT acceptable.
Invert gently 5 times to mix. Handle gently to prevent platelet activation.
Sample must be hand delivered to the testing lab < 2 hours post collection,
CANNOT be sent through the pneumatic tube system.
Use 21 gauge needle
Collect the required discard tube and completely- filled 4.0 mL sodium or lithium heparin green top tube. GEL tubes are NOT acceptable.
Invert gently 5 times to mix. Handle gently to prevent platelet activation.
Sample must be hand delivered to the testing lab < 2 hours post collection,
CANNOT be sent through the pneumatic tube system.
Transport Container
4 mL whole blood Sodium Heparin or Lithium green top tube.
Specimen Stability
Room Temperature: Whole blood Sodium heparin or Lithium Heparin < 2 hours
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Rejected for hemolysis, clotted, improper fill, incorrect specimen type, refrigerated plasma or blood, expired test tubes, > 2 hours old.
Methodology
Viscoelastic
Setup Schedule
Sunday through Saturday (24/7)
MVH and Atrium Laboratory
MVH and Atrium Laboratory
Report Available
90 minutes
Limitations
Sample stability once collected is <2 hours
Reference Range
See report
Clinical Significance
The TEG instrument with cartridge utilizes a whole blood sample to analyze the process of clot formation and lysis. The results are displayed in a table and on a graphical tracing that reflects the hemostasis profile of clot formation and fibrinolysis on the sample submitted for testing.
Last Updated: November 15, 2022