Lead, Urine [601]

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
LEADUR


Alias/See Also
601


CPT Codes
82570, 83655

Includes
Creatinine


Preferred Specimen
7 mL urine collected in a acid-washed, or metal-free container


Minimum Volume
3 mL


Instructions
Avoid work-site collection.
Note: Test performed on a specimen submitted in a nontrace element tube/container (not acid-washed) may not accurately reflect the patient's level. If a nontrace element tube/container is received, it will be accepted for testing; however, elevated results are reported with a message that resubmission with a trace element tube/container is recommended.


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 48 hours
Refrigerated: 5 days
Frozen: 14 days


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat p.m.; Report available: 1 day


Reference Range
Lead, Urine
Non-exposed Adult <10 mcg/g creat
Creatinine, Random Urine
≤6 Months 2-28 mg/dL
7-11 Months 2-31 mg/dL
1-2 Years 2-110 mg/dL
3-8 Years 2-130 mg/dL
9-12 Years 2-160 mg/dL
>12 Years Male 20-320 mg/dL
>12 Years Female 20-275 mg/dL


Clinical Significance
Elevated urinary lead concentration is indicative of chronic lead toxicity. Urinary lead concentrations may be used to monitor detoxification therapy.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153


Last Updated: November 30, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.