Intact PTH And Calcium

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
PTHI


Alias/See Also
8837;
Parathyroid;
PTH;
PTH Assay;
PTH, Intact;
PTH, Intact (IRMA) & Calcium;
Parathyroid Hormone Level


CPT Codes
82310;83970

Includes
Includes: PTH Intact, Calcium (70167)


Preferred Specimen
serum


Minimum Volume
1 mL


Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.


Transport Container
Original tube preferred, may be sent in a screw-top transfer tube.


Transport Temperature
Refrigerated or Frozen


Specimen Stability
Room Temperature = 8 hours
Refrigerated = 2 days
Frozen = 6 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.


Methodology
immunoassay

Setup Schedule
DAILY
AU


Report Available
daily


Clinical Significance
The assay is useful in making the diagnosis of primary hyperparathyroidism, secondary hyperparathyroidism, and a differential diagnosis of hypercalcemia. The assay helps in distinguishing hypercalcemia cause by either primary hyperparathyroidism or malignant disease.


Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439


Last Updated: November 22, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.