Platelet Count

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
PLTC


Alias/See Also
70234;
Platelet;
PLT;
Plt Count;
Thrombocytes Count;


CPT Codes
85049

Preferred Specimen
3 mL or 4 mL whole blood K2EDTA (lavender top) tube(s) or K2EDTA (Microtainer® lavender top) tube(s). 


Minimum Volume
Minimum fill 1 mL (Microtainer® filled between the 2 lines).


Instructions
Avoid hemolysis. Gently invert 10 times immediately at time of collection.


Transport Container
K2EDTA (lavender top) tube


Transport Temperature
Refrigerated


Specimen Stability
Room Temperature = 24 hours
Refrigerated = 48 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Rejected for gross hemolysis, clotted, <1 mL, non-EDTA tube type, >48 hours old, frozen.


Methodology
Automated Cell Counter, Review of peripheral smear if criteria is met.

Setup Schedule
Sunday - Saturday
HE


Limitations
Platelet clumping, if present an estimate will be given i.e. Decreased, adequate or increased. A numeral result is not possible if clumping is present.


Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439


Last Updated: August 4, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.