Glucose

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
GLUB


Alias/See Also
484;
RBS (R INDICATES RANDOM);
RANDOM BLOOD SUGAR;
SERUM GLUCOSE;
FASTING BLOOD SUGAR (S);
FASTING GLUCOSE (P);
FASTING GLUCOSE (S);
GLUCOSE;
GLUCOSE (P);
1 HOUR POST PRANDIAL;
1 HOUR PP;
1


CPT Codes
82947

Preferred Specimen
SST/GST Serum Only


Minimum Volume
1 mL


Other Acceptable Specimens
plasma from Lithium Heparin (Light Green Top)tube


Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. Red top serum unacceptable for testing.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.


Transport Container
Original tube preferred, may be sent in a screw-top transfer tube.


Transport Temperature
Room Temperature or Refrigerated


Specimen Stability
Room Temperature = 5 days
Refrigerated = 5 days
Frozen = n/a


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.


Methodology
Spectrophotometric

Setup Schedule
24/7
AU


Report Available
daily


Clinical Significance
Plasma glucose levels may be abnormally high (hyperglycemia) or abnormally low (hypoglycemia). Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolic disorders including diabetes mellitus, idiopathic hypoglycemia, and pancreatic islet cell neoplasm.


Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439


Last Updated: November 22, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.