HTLV I/II Antibody, with Reflex to Confirmatory Assay [36175]

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
HTLV


Alias/See Also
36175


CPT Codes
86790

Includes
If HTLV-I/II Antibody is Reactive, then HTLV-I/II Antibody, Confirmatory Assay will be performed at an additional charge (CPT code(s): 86689)


Preferred Specimen
2 mL serum


Minimum Volume
1 mL


Other Acceptable Specimens
Plasma collected in: EDTA (lavender-top) tube


Instructions

Label the tubes according to your standard operating procedure, making sure that each tube has at least two unique patient identifiers.

If transport temperature will be frozen, centrifuge the red/lavender-top and transfer the serum/plasma into a plastic, screw-cap vial. The plastic, screw-cap vial (aliquot tube) containing serum or plasma must be labeled with the specimen type (serum or plasma) and at least two unique identifiers. Aliquot tubes must be processed and labeled at the original collection site. If aliquot tubes are submitted, do not send the original red/lavender-top.

Room temperature transport is acceptable. Do not store at room temperature.



Transport Container
Transport tube


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: See instructions
Refrigerated: 14 days
Frozen: 30 days


Methodology
Screen: Immunoassay (IA) • Confirmation: Immunoblot (IB)

Setup Schedule
Set up: Daily; Report available: 36 hours (reflex: 2-7 days)


Reference Range
Non-Reactive


Clinical Significance
HTLV-I is associated with adult T-cell lymphoblastic leukemia and B-cell chronic lymphocytic leukemia. HTLV-II is less common and is associated with neoplasias of the CD8 T lymphocytes. Blood donor screening began in 1998.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153


Last Updated: November 30, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.