ALPHA 1 ANTITRYPSIN

Test Code
A1AT


Alias/See Also
ALPHA 1-PROTEASE INHIBITOR


CPT Codes
82103

Preferred Specimen
1mL serum 


Minimum Volume
0.5 mL serum


Instructions
Barrier tubes (serum separator tubes) are preferred. If non-barrier tubes are utilized, the serum must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.


Transport Container
Original tube preferred, may be sent in a screw-top transfer tube.


Transport Temperature
Room temperature


Specimen Stability
Room Temperature:  24 hours
Refrigerated: 7 days
Frozen: at least 7 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, contaminated sample.


Methodology
Immunoturbidimetric Assay

Setup Schedule
Monday and Thursday
BS


Report Available
1-5 days


Reference Range
Normal adult serum: 90 – 200 mg/dL 


Clinical Significance
Alpha-1-Antitrypsin level may be increased in normal pregnancy and in several diseases including chronic pulmonary disease; hereditary angioedema; renal, gastric, liver and pancreatic diseases; diabetes; carcinomas and rheumatoid diseases. Alpha-1-Antitrypsin may be decreased in emphysema, hepatic cirrhosis, respiratory distress syndrome of the newborn, nephrosis, malnutrition and cachexia. 


Performing Laboratory
CompuNet Clinical Laboratories, LLC
Serology Department
2308 Sandridge Drive
Moraine, Ohio 45439


Last Updated: February 14, 2024


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.