Reflex TSH

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.

If TSH is abnormal, a reflex order for Free T4 is added at an additional charge


Test Code
RTSH


Alias/See Also
36127;
TSH w/Reflex


CPT Codes
84443

Includes
Reflex to Free T4 (71124) if TSH is <0.1 or >10.0 at an additional charge (CPT code(s)84439) .


Preferred Specimen
serum


Minimum Volume
1.0 mL


Other Acceptable Specimens
plasma from Lithium Heparin (Light Green Top) tube


Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.


Transport Container
Original tube preferred, may be sent in a screw-top transfer tube.


Transport Temperature
Room Temperature or Refrigerated


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, contaminated sample.


Methodology
Immunoassay

Setup Schedule
24/7
AU


Report Available
daily


Performing Laboratory
Compunet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439


Last Updated: December 7, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.