Resources

RUBELLA ANTIBODY, IGG

Message

Immunity



Test Code
RUBG


Alias/See Also
German Measles; Measles; Measles IgG


CPT Codes
86762

Preferred Specimen
1 Gold tube (gel separator)


Minimum Volume
0.3 mL


Instructions
Centrifuge for complete separation of serum and red cells.  Separate and refrigerate until tested.


Transport Temperature
Refrigerate


Specimen Stability
2-8°C up to 7 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis interferes


Methodology
CIA

Setup Schedule
M, T, W, Th, F


Report Available
Report available within 24 hours of receipt at the performing laboratory.


Reference Range
  • >/=10 IU/mL = IMMUNE
  • 8 - 9 IU/mL = EQUIVOCAL

 



Clinical Significance

The presence of at least 10.0 International Units (IU) of antibody per mL of sample is indicative of immunity or past exposure to rubella virus Antibody levels below 10.0 IU/mL may be insufficient to provide protection from clinical illness upon exposure to rubella.




Performed By
Alverno Laboratories

Performing Laboratory
Alverno Central Lab  
NIM5 (Immunology, Bioplex)


Last Updated: April 15, 2024


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.