Resources

LIVER HEPATIC PANEL

Message
Protect from light
Please note:  Samples do not need to be wrapped to protect from light.  Samples stored in an amber tube or dark refrigerator can be accepted.


Test Code
HFP2


Alias/See Also
Liver Function


CPT Codes
80076

Includes
Includes: Albumin, SGOT, Alk Phos, Total Bilirubin, Direct Bilirubin, SGPT, Total Protein


Preferred Specimen
1 Gold tube (gel separator)


Minimum Volume
1 mL


Other Acceptable Specimens
or 1 Green tube (Lithium Heparin)



Instructions
Centrifuge for complete separation of serum or plasma and red cells.  To protect from light, serum or plasma can be aliquotted (transferred) into an amber transfer tube, wrapped, or stored in a dark refrigerator.  Refrigerate until tested.


Transport Temperature
Refrigerate


Specimen Stability
  • 2-8°C up to 3 days if protected from light
  • 2-8°C up to 24 hours if not protected from light
  • Frozen up to 3 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolyzed


Methodology
See individual tests

Setup Schedule
M, T, W, Th, F, Sa, Sun


Report Available
​Within 24 hours of receipt at the performing laboratory.  Stat testing is available.


Reference Range

See individual tests for reference ranges.



Clinical Significance
Evaluation and monitoring of liver function


Performed By
Alverno Laboratories

Performing Laboratory
Alverno Central Lab  
NCHB1 (Chemistry, Beckman AU)


Last Updated: June 9, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.