Resources

ALLERGEN, EGG WHITE (f1) w/ REFLEX TO ALLERGEN PROFILE, EGG COMPONENT

Message
The Egg Component Panel will reflex automatically egg white (f1) allergy result is positive.


Test Code
AGEWR


CPT Codes
86003; 86008 x2 if reflexed

Includes

Ovalbumin, Ovomucoid



Preferred Specimen
1 Gold tube (gel separator)


Minimum Volume

1 mL



Other Acceptable Specimens
1 Pearl tube (gel separator)


Instructions

Centrifuge for complete separation of serum or plasma from red cells. Refrigerate until tested.




Transport Temperature

Refrigerate



Specimen Stability

2-8°C up to 7 days; otherwise freeze at -20°C or lower



Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)

Quantity not sufficient

Samples received that are not separated from red cells will be rejected



Methodology

FEIA/ImmunoCAP



Setup Schedule

M, W, F (day shift only)



Report Available
Same day tested.


Reference Range

<0.35 kU/L



Clinical Significance
Aids in identifying the egg-specific proteins that are responsible for allergic response in patients with egg allergy. This, in turn is useful in assessing the level of risk and severity of allergic reaction.


Performed By
Alverno Laboratories

Performing Laboratory
Alverno Central Lab  
NIM7 (Immunology, Phadia Immunocap)


Last Updated: December 28, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.