A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
MYOGLOBIN, SERUM or PLASMA
Test CodeMYO2
CPT Codes
83874
Preferred Specimen
1 Green tube (Lithium Heparin)
Minimum Volume
0.2 mL
Other Acceptable Specimens
1 Gold tube (gel separator) or
1 Lavender tube (EDTA)
1 Lavender tube (EDTA)
Instructions
Centrifuge samples within 2 hours of collection. If testing cannot be completed within 24 hours, freeze serum or plasma.
Transport Temperature
Refrigerate
Specimen Stability
- 2-8°C up to 24 hours
- 15-30°C up to 8 hours
- Frozen samples are stable
Methodology
Chemiluminescent immunoassay
Setup Schedule
M, T, W, Th, F, Sa, Sun
Report Available
Within 24 hours of receipt at the performing laboratory.
Reference Range
Sex | Reference Range (ng/mL) |
Male | 17.4 - 105.7 |
Female | 14.3 - 65.8 |
Clinical Significance
Myoglobin is released into the bloodstream following injury to skeletal or cardiac muscle. We cannot distinguish origin for elevated myoglobin levels. Due to the lack of specificity, myoglobin is not recommended for diagnosis of myocardial injury (AMI).
Performed By
Alverno Laboratories
Performing Laboratory
Alverno Central Lab
NCHB2 (Chemistry, Beckman DxI)
Last Updated: April 23, 2024