A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
IRON
Test CodeIRON
CPT Codes
83540
Preferred Specimen
1 Gold tube (gel separator)
Minimum Volume
0.5 mL
Other Acceptable Specimens
or 1 Green tube (Lithium Heparin)
Instructions
Centrifuge for complete separation of plasma or serum and red cells. Separate and refrigerate until tested.
Transport Temperature
Refrigerate
Specimen Stability
- 15-30°C up to 4 days
- 2-8°C up to 7 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
The following conditions will result in a rejected sample:
- Hemolyzed samples
- Samples collected in EDTA, Oxalate, or Citrate anticoagulants
Methodology
TPTZ - no deproteinization
Setup Schedule
M, T, W, Th, F, Sa, Sun
Report Available
Within 24 hours of receipt at the performing laboratory.
Reference Range
50 - 212 ug/dL
Clinical Significance
Iron (non-heme) measurements are used in the diagnosis and treatment of diseases such as iron deficiency anemia, hemochromatosis, and chronic renal disease. Transferrin is the major iron carrying protein in the serum.
Performed By
Alverno Laboratories
Performing Laboratory
Alverno Central Lab
NCHB1 (Chemistry, Beckman AU)
Last Updated: June 9, 2023