Resources

AMIKACIN, RANDOM

Message

Cannot use heparin tubes. Heparin has been shown to interfere with the measurement of Amikacin.




Test Code
AMKR2


CPT Codes
80150

Preferred Specimen
1 Red tube


Minimum Volume

0.5 mL



Other Acceptable Specimens
1 Lavender tube (EDTA) or
1 Gold tube (gel separator)


Instructions
Centrifuge for complete separation of plasma or serum from red cells.  Aliquot/transfer serum or plasma into transfer tube. Refrigerate until tested.


Transport Temperature
Refrigerate


Specimen Stability

2-8°C up to 7 days; Alternate storage temperatures are not available




Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)

Samples will be rejected if submitted in a heparin tube




Methodology

EIA



Setup Schedule
M, T, W, Th, F, Sa, Sun


Report Available
Within 24 hours of receipt at the performing laboratory.


Reference Range
Peak 20-30 µg/mL
Random 1-30 µg/mL
Trough 1-8 µg/mL

 



Clinical Significance
Monitors dosage of the aminoglycoside used in the treatment of gram negative infections.


Performed By
Alverno Laboratories

Performing Laboratory
Alverno Central Lab  
NCHB1 (Chemistry, Beckman AU)


Last Updated: June 8, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.