ALT
Test CodeALT
Alias/See Also
Alanine Aminotransferase;SGPT
CPT Codes
84460
Preferred Specimen
1 Gold tube (gel separator)
Minimum Volume
0.5 mL
Other Acceptable Specimens
or 1 Green tube (Lithium Heparin)
Instructions
Centrifuge for complete separation of plasma/serum and red cells. See Specimen Container for appropriate sample type. Separate and refrigerate until tested.
Specimen Stability
2-8°C up to 3 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolyzed
Methodology
UV without P5P at 37°C
Setup Schedule
M, T, W, Th, F, Sa, Sun
Reference Range
7 - 52 U/L
Clinical Significance
This enzyme is a sensitive indicator of active liver damage but does not indicate the cause or reversibility of the damage. Increased serum ALT activity indicates recent or ongoing liver cell damage.
Performed By
Alverno Laboratories
Performing Laboratory
Alverno Central Lab
NCHB1 (Chemistry, Beckman AU)