A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Lactate Dehydrogenase (LD), Peritoneal fluid : 17588
Test CodeLDPERT or 17588
CPT Codes
83615
Transport Container
Preferred Specimen
1 mL peritoneal fluid collected in transport tube
Minimum Volume
0.5 mL
1 mL peritoneal fluid collected in transport tube
Minimum Volume
0.5 mL
Transport Temperature
Frozen.
Specimen Stability
Room temperature: 1 day; Refrigerated: 7 days; Frozen: 28 days
Methodology
Spectrophotometry
Setup Schedule
Sunday - Saturday
Report Available
1 day
Reference Range
<63 U/L
Clinical Significance
The most reliable tests for differentiating between the transudates and exudates are the simultaneous analysis of peritoneal fluid and serum from lactic dehydrogenase (LD) and total protein levels. The main usefulness in defining serous body fluids as a transudate or exudate is to determine which effusions need further laboratory evaluation.
Performing Laboratory
med fusion