Cryptococcus Antigen Screen, Serum : 1000249

Test Code
CRYPGT or 1000249


Alias/See Also
Cryptococcus Ag Screen, S


CPT Codes
86403

Includes
If screen is positive, Cryptococcus Antigen titer will be performed at an additional charge (CPT code(s): 86406).


Instructions
Plain red top tube.


Transport Container
Centrifuge the plain red top tube and aliquot serum (Min. 1 mL) into a standard transport tube.


Transport Temperature
Refrigerated.


Specimen Stability
Ambient: Unacceptable; Refrigerated: 7 days; Frozen: 7 days


Methodology
Immunochromatographic lateral flow assay

Setup Schedule
Sunday - Saturday


Report Available
1-2 days


Reference Range
Negative


Clinical Significance
The cryptococcal antigen lateral flow assy is an immunochomatographic test system for the detection of the polysaccharide antigens of Cryptococus neoformans and Cryptococcusgattii in serum and cerebral spinal fluid (CSF). It uses a dipstick sandwich technique with specimen wicking to detect cryptococcal antigen using highly specific monoclonal antibodies. Cryptococcosis is cause by both C. neoformans and C. gattii. Individuals with impaired cell mediated immunity are at greatest risk of infection. Cryptococcosis is one of the most common opportunistic infections in AIDS patients. Detection of cryptococcal antigen in serum and CSF has been extensively utilized with very high sensitivity and specificity.


Performing Laboratory
med fusion



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.