Anti-Nuclear Antibodies, IFA, with Reflex to Multiplex Antibody Comprehensive : 1003718

Test Code
ANACOM or 1003718


Alias/See Also
Lupus Testing; ANA; Antinuclear Antibodies; Connective Tissue Disease; Autoantibody Testing


CPT Codes
86038

Includes
If the ANA by IFA is positive, a titer will be performed at an additional charge (CPT code(s): 86039). If the ANA by IFA is positive at a titer >=1:80, then the ENA panel will be performed at an additional charge. ENA panel includes: SSA, SSB, RNP, SMITH, Jo-1, Scl-70, ds DNA multiplex flow, Centromere, Chromatin, Ribosomal P, and SmRNP. (CPT code(s): 86225, 83516, 86235 x9).


Preferred Specimen
1 mL serum


Instructions
Serum separator tube (gold top preferred) or a plain red top tube.


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 4 days
Refrigerated: 7 days;
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis, grossly lipemic, microbial contamination may interfere


Methodology
Indirect Immunofluorescence; Multiplex Flow Immunoassay

Setup Schedule
Monday - Saturday


Report Available
1-3 days


Reference Range
ANA Screen, IFA: Negative
ANA Titer: <1:80 
ANA Pattern: None
ANA Titer 2: <1:80 
ANA Pattern 2: None

     
If reflex to ENA then all analytes Negative with the exception of dsDNA.
dsDNA : 
   Negative <or = 4 IU/mL
   Indeterminate 5-9 IU/mL
   Positive  > or = 10 IU/mL


Clinical Significance
Used as an aid in the diagnosis of systemic autoimmune diseases.


Performing Laboratory
med fusion



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.