Platelet Antibodies, Indirect (IgG, IgM) : 91744

Test Code
PLTGMQ or 91744


Alias/See Also
Circulating Platelet Antibody, Serum Platelet Antibody


CPT Codes
86022X2

Instructions
Serum separator tube or plain red tube.


Transport Container
Centrifuge serum separator tube and transport. If plain red, centrifuge and aliquot 2 mL serum (Min: 1 mL) into a standard transport tube.


Transport Temperature
Refrigerated.


Specimen Stability
Ambient: Unacceptable; Refrigerated: 21 days; Frozen: Unacceptable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis. Lipemia. Icterus.


Methodology
Flow Cytometry (FC)

Setup Schedule
Tuesday & Thursday


Report Available
2-5 days (From receipt at performing laboratory)


Limitations
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.


Reference Range
Platelet Ab, Indirect (IgG) Negative
Platelet Ab, Indirect (IgM) Negative


Clinical Significance
Circulating antibodies to platelets have been associated with immune and drug-induced thrombocytopenia. Elevated levels of platelet - associated antibodies may occur in autoimmune thrombocytopenia, as well as thrombocytopenia associated with carcinoma, AIDS, and connective tissue diseases. Both circulating and associated platelet antibodies may play a role in platelet destruction. Platelet antibodies may consist of a single isotype or any combination of isotypes.


Performing Laboratory
Quest Diagnostics



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.