Amiodarone : 36721

Test Code
AMIODE or 36721


CPT Codes
80151

Instructions
Centrifuge and immediately separate serum or plasma specimen from the cells into a clean transport tube. Do not use gel barrier/serum separator tube (SST).


Transport Container
Preferred Specimen
3 mL serum in a red-top tube (no gel)

Minimum Volume
1 mL
  
Alternative Specimen:
Plasma collected in EDTA (lavender-top) tube, sodium heparine (green-top tube) or lithium heparin (green-top) tube


Transport Temperature
Refrigerated.


Specimen Stability
Room temperature: 48 hours; Refrigerated: 4 days; Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis; Lipemia; Gel barrier / Serum Separator Tube (SST®)


Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

Setup Schedule
Tuesday, Thursday, Saturday


Report Available
2-4 days


Reference Range
Amiodarone                  1.5-2.5 mcg/mL


Desethylamiodarone     1.5-2.5 mcg/mL


Toxic                               >2.5 mcg/mL


 


Toxic effects have been observed at levels as low as 2.0 mcg/mL



Clinical Significance
Amiodarone is an antiarrhythmic drug. Therapeutic drug monitoring is useful to monitor compliance and avoid toxicity.


Performing Laboratory
med fusion



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.