A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
OXYCODONE, RANDOM URINE
Test CodeLAB1892
CPT Codes
80301
Preferred Specimen
Urine, random specimen in a clean plastic collection cup
Minimum Volume
2 mL urine
Required for testing: 1 mL urine
Required for testing: 1 mL urine
Transport Temperature
Refrigerated
Specimen Stability
Ambient: 24 hours Refrigerated: 5days Frozen: notspecified
Methodology
Enzyme Immunoassy
Setup Schedule
Sunday- Saturday
Reference Range
Negative
Clinical Significance
Cutoff for presumptive positive result: 100 ng/mL
Approximate detection time in urine: <24 hours
Calibrator: Oxycodone
Lowest Drug concentrations producing a POSITIVE RESULT
Concentrations of the following structurally unrelated compounds produce a NEGATIVE RESULT on this test
Approximate detection time in urine: <24 hours
Calibrator: Oxycodone
Lowest Drug concentrations producing a POSITIVE RESULT
Compound | Cutoff Concentration (ng/mL) |
Oxycodone | 100 |
Oxymorphine | 300 |
Concentrations of the following structurally unrelated compounds produce a NEGATIVE RESULT on this test
Analyte | Concentration |
Acetone | 1.0 g/dL |
Ascorbic Acid | 1.5 g/dL |
Bilirubin | 0.002 g/dL |
Creatinine | 0.5 g/dL |
Ethanol | 1.0 g/dL |
y-Globulin | 0.5 g/dL |
Hemoglobin | 0.300 g/dL |
Human Serum Albumin | 0.5 g/dL |
Oxalic Acid | 0.1 g/dL |
Riboflavin | 0.0075 g/dL |
Sodium Azide | 1% w/v |
Sodium Citrate | 6.0 g/dL |
Sodium Fluoride | 1 % w/v |
Urea | 6.0 g/dL |
Ph | 3,4,5,6,7,8,9,10 and 11 |
Specific Gravity | 1.000, 1.002 , 1.005, 1.010, 1.015, 1.020, 1.025, and 1.030 |
Performing Laboratory
West Virginia University Hospital, Inc.
United Hospital Center