CYCLOSPORINE PEAK (C2)

Message
Trough levels are drawn prior to the next scheduled dose. Peak levels should be drawn 2 hrs post-dose.


Test Code
LAB304425


CPT Codes
80158

Preferred Specimen
One 3 mL lavender top tube
Pediatric: One lavender top microtainer


Instructions
Specify dosage history. Time drawn must be written on label.


Transport Temperature
Refrigerated


Specimen Stability
Ambient: 24 hours   Refrigerated: 7 days   Frozen: not specified


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Clotted specimen or serum samples


Methodology
Chemiluminescent Immunoassay

Setup Schedule
Sunday-Saturday Note: Testing will be performed twice per day; 12 noon and 8 pm (specimens must be received in the laboratory prior to the testing times in order to be run that day).


Reference Range
Therapeutic level: 800-1500 ng/mL (Peak)
Toxic level: ≥1500 ng/mL


Clinical Significance
Monitoring whole blood cyclosporine concentration during therapy, particularly in individuals coadministered CYP3A4 substrates,
inhibitors, or inducers.
Adjusting dose to optimize immunosuppression while minimizing toxicity.
Evaluating patient compliance


Performing Laboratory
West Virginia University Hospital, Inc.



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.