A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
ANAEROBIC CULTURE
Test CodeLAB233
CPT Codes
87075
Includes
Culture for anaerobic organisms.
Preferred Specimen
Specimen in a sterile leak-proof container
Other Acceptable Specimens
Capped syringe or appropriate anaerobic transport medium. Examples of appropriate anaerobic specimens: sterile tissue, aspirates (collected with a needle and syringe), deep wound specimens collected surgically and transported anaerobically and foreign bodies removed surgically such as valves or metal plates that are then transported anaerobically.
Transport Temperature
Ambient
Specimen Stability
Ambient: 24 hours
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Anaerobic culture cannot be performed on specimens exposed to atmospheric oxygen (e.g.Culturette swabs). Routine aerobic culture will be performed on any specimen received on Culturette swabs. The following specimens are not acceptable for anaerobic culture: voided or catheterized urine,swabs from open wounds, drainages, expectorated sputum, tracheal secretions, bronchial washes, bile fluid, stool and swabs from the throat, ear or eye.
Methodology
Culture
Setup Schedule
Sunday-Saturday
Reference Range
No anaerobes isolated.
Performing Laboratory
West Virginia University Hospital, Inc.
Berkeley Medical Center
Camden Clark Medical Center
Jackson General Hospital
Jefferson Medical Center
Reynolds Memorial Hospital
United Hospital Center