CYTOMEGALOVIRUS (CMV), QUALITATIVE PCR, CSF, URINE

Test Code
LAB304320


CPT Codes
87496

Preferred Specimen
CSF in a sterile vial or
Urine in a sterile collection cup


Minimum Volume
All sample types require 1.2 mL of specimen


Instructions
Place aliquoted CSF, or urine samples in the -20 freezer in the rack marked Molecular Diagnsotics, frozen samples


Transport Temperature
Frozen


Specimen Stability
Frozen (-20): 4 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Non-validated Specimen Types will be forward to Reference Laboratories  Testing on samples stored incorrectly or with insufficient volume will be cancelled. Heparin MUST NOT be added to sterile containers because heparin inhibits PCR reactions.


Methodology
Real Time PCR using a Laboratory Developed Test (LDT)

Setup Schedule
Monday, Wednesday and Friday


Reference Range
Negative


Performing Laboratory
West Virginia University Hospital, Inc.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.