LACTIC ACID REFLEXIVE TEST FOR SEPSIS CORE MEASURES

Message
Used for baseline testing in septic patients, when core measures for repeat testing apply.


Test Code
LAB1237164


CPT Codes
83605

Includes
When "Lactic Acid with Reflex" (LAB1237164) is ordered, a baseline lactic acid level will be measured.
If the baseline lactic acid is >2.0 mmol/L, a follow-up lacticacid test will be automatically ordered, with a collect time 2 hours in the future.
If the baseline lactic acid is < 2.0 mmol/L, no reflexive follow-up test will be ordered. Any additional testing would be ordered by the care team.


Preferred Specimen
One 4 mL gray top tube on ice
Pediatric Volume: One gray top microtainer on ice.


Instructions
Sample should be immediately placed on ice after collection and transported to the lab without delay. Sample must be centrifuged immediately after collection. Serum/Plasma must be removed from the red cells and put inot aliquot tubes following centrifugation.


Transport Temperature
On Ice


Specimen Stability
Unstable, transport to lab ASAP
Ambient: Unstable  Refrigerated: 3 days  Frozen: 3 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens not received on ice and/or with gross hemolysis.


Methodology
Lactate to Pyruvate

Setup Schedule
Sunday- Saturday


Reference Range
Reference Interval: 0.5-2.2 mmol/L
Critical level:≥4.0 mmol/L


Performing Laboratory
West Virginia University Hospital, Inc.
Bluefield Pavilion Campus
Berkeley Medical Center
Barnesville Hospital
Braxton County Memorial
Camden Clark Medical Center
Camden Clark Medical Center
Fairmont Medical Center
Garrett Regional Medical Center
Harrison Community Hospital
Jackson General Hospital
Jefferson Medical Center
Princeton Community Hospital
Potomac Valley Hospital
Reynolds Memorial Hospital
Summersville Regional Medical Center
St. Joseph’s Hospital
United Hospital Center
Uniontown Hospital
Wetzel County Hospital
Wheeling Hospital




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.