ECSTASY (MDMA), RANDOM URINE

Test Code
LAB1880


Preferred Specimen
Urine, random specimen in a clean plastic collection cup


Minimum Volume
2 mL urine


Instructions
Required for testing: 1 mL urine


Transport Temperature
Refrigerated


Specimen Stability
Stability:    Ambient: 24 hours     Refrigerated: 5days     Frozen: notspecified


Methodology
Enzyme Immunoassay

Setup Schedule
Sunday- Saturday


Reference Range
Negative


Clinical Significance
Interpretive Information
Cutoff for presumptive positive result: 500 ng/mL
Approximate Detection Time in Urine: 72 hours
Calibrator: MDMA at 500 ng/mL

Lowest Drug concentrations producing a POSITIVE RESULT
Compound Concentration Tested
(ng/mL)
MDA 900
MDEA 600
MBDB 2000
BDB 1500
para-Methoxyamphetamine (PMA) 4700
para-Methoxymethamphetamine (PMMA) 1700

Concentrations of these structurally similar compounds produce a NEGATIVE RESULT on this test
Compound Concentration Tested
(ng/mL)
d-Amphetamine 600 000
l-Amphetamine 90 000
d,l-Amphetamine 180 000
l-Ephedrine 800 000
d-Methamphetamine 600 000
l-Methamphetamine 62 000
d,l-Methamphetamine 100 000
Phentermine 220 000
d,l-Phenylpropanolamine 800 000
d-Pseudoephedrine 1 000 000

Concentrations of these structurally unrelated compounds produce a NEGATIVE RESULT on this test
Compound Concentration Tested
(ng/mL)
Acetaminophen 1 000 000
Acetylsalicylic acid 1 000 000
Amoxicillin 1 000 000
Benzoylecgonine 1 000 000
Caffeine 100 000
Captopril 1 000 000
Chlordiazepoxide 250 000
Cimetidine 500 000
Codeine 1 000 000
Diazepam 1 000 000
Digoxin 100 000
Enalapril 1 000 000
Fluoxetine 500 000
Ibuprofen 1 000 000
Levothyroxine 100 000
Methadone 1 000 000
Morphine 1 000 000
Nifedipine 50 000
Phencyclidine 1 000 000
Phenobarbital 1 000 000
Propoxyphene 1 000 000
Ranitidine 250 000
Salicyluric acid 1 000 000
THC 10 000
Tolmetin 500 000
Verapamil 1 000 000


Performing Laboratory
West Virginia University Hospital, Inc.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.