OPIATES CONFIRMATORY/ DEFINITIVE, URINE, BY LC-MS/MS

Message
  • Definitive compliance checks in patients prescribed codeine, dihydrocodeine, hydrocodone, hydromorphone, morphine,  oxycodone, and/or oxymorphone
  • Confirming presumptive positive screening tests for opiates. [Urine quantitative values do NOT correlate well with serum concentrations and should not be used for assessing dose efficacy or timing.]


Test Code
LAB1230610


CPT Codes
80307

Includes
Quantitative/definitive detection of opiates that can cross-react and yield positive opiate screening results. Quantitative results are only provided for positive results; negative results will have an interpretation of “Negative” and a component result of “Not detected”. [Urine quantitative values do NOT correlate well with serum concentrations and should not be used for assessing dose efficacy or timing.]
Adulteration testing is provided at no-charge and includes urine creatinine


Preferred Specimen
Urine, random specimen clean plastic collection cup
Pediatric: 3mL Urine


Minimum Volume
5mL


Instructions
Specimens collected in clean plastic collection cups are acceptable. Store refrigerated for best stability.
Transfer mixed urine specimen to a labeled red top tube and deliver to Chemistry department for track-based processing, adulteration testing,
and aliquoting for use in the mass spectrometry section.


Transport Temperature
Refrigerated


Specimen Stability
 Ambient: 24 hours   Refrigeared: 10 days


Methodology
LC-MS/MS

Setup Schedule
Monday thru Friday Dayshift


Reference Range
Negative


Clinical Significance
Cutoffs:
Codeine, 25 ng/mL
Dihydrocodeine, 25 ng/mL
Hydrocodone, 25 ng/mL
Hydromorphone, 25 ng/mL
Morphine, 25 ng/mL
Norhydrocodone, 25 ng/mL
Noroxycodone, 25 ng/mL
Oxycodone, 25 ng/mL
Oxymorphone, 25 ng/mL


Performing Laboratory
West Virginia University Hospitals, Inc.

Additional Information
Test Change Notification


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.