LUNG CANCER, ROS1 (6Q22) REARRANGEMENT, FISH, TISSUE

Test Code
LAB1237095


CPT Codes
88271, 88275, 88291

Preferred Specimen
Tissue: TissueBlock (preferred)  Submit formalin-fixed,paraffin-embedded (FFPE) tumor tissue slides. Unstained surgical slides cut 3 microns thick. Also submit one H&E (3 microns thick) marked by pathologist for malignant area.


Minimum Volume
2 unstained slides and 1 H&E .


Instructions
PLACE IN CYTOGENTIC’S BUCKET NEAR CHEMISTRY


Transport Temperature
Ambient or refrigerated (prolonged transport conditions)


Specimen Stability
Block/Slides : Ambient(preferred). NEVER FROZEN


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Tissue: Necrosis of Tissue sample or inappropriate tissue fixation


Methodology
Fluorescent In Situ Hybridization (FISH)

Setup Schedule
Samples processed Monday through Saturday. Results reported Monday through Friday


Reference Range
An interpretive report will be provided.


Performing Laboratory
West Virginia University Hospital, Inc.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.