Aquaporin-4 (AQP4) (NMO-IgG) Antibody with Reflex to Titer, CSF

Test Code
38323


Alias/See Also
LAB15183


CPT Codes
86052

Includes
If the Aquaporin 4 Antibody, CSF is positive, then Aquaporin 4 Antibody, Titer, CSF will be performed at an additional charge (CPT code: 86052).


Preferred Specimen
2 mL CSF collected in a sterile, plastic screw-cap vial


Minimum Volume
0.5 mL


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 7 days
Refrigerated: 14 days
Frozen: 21 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Visible particulate matter


Methodology
Cell-based Immunofluorescence Assay

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Thursday, Sunday Morning Report available: 4 Days


Reference Range
Aquaporin 4 Ab, CBA, CSF Negative
  Aquaporin 4 Ab, Titer, CSF <1:10 Titer


Clinical Significance
NMO (neuromyelitis optica, Devic disease) is an immune- mediated chronic inflammatory disease that predominantly affects the optic nerve and spinal cord and presents with optic neuritis (ON) and myelitis. Limited forms of this disease, such as isolated ON, brainstem encephalitis and longitudinal extensive transverses myelitis (LETM), have been referred to as NMO spectrum disorders (NMOSD). NMO was originally thought to be a variant of multiple sclerosis, but is now recognized as a distinct disease. The presence of serum antibodies against aquaporin-4 (AQP4) is associated with NMO and NMOSD.


Performing Laboratory
Quest Diagnostics Nichols Institute
33608 Ortega Hwy
San Juan Capistrano, CA 92675-2042



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.