| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
GASTROINTESTINAL (GI) BACTERIAL PANEL W/ REFLEX TO GI EXTENED PANEL PCR, Panther
MessageAny specimen received with orders of stool culture; the stool culture will be cancelled, and the GI Bacterial Panel PCR Assay will be performed.
GI Bacterial Panel with Reflex to GI Extended Panel, PCR Panther must be order seperately.
Note: If a GI Bacterial Panel PCR testing performed prior (≤3days), put in an additional test ordered and contact the Molecular department to add on the GI Extended Panel.
This assay is a multiplex real-time PCR intended to aid the differential diagnosis of individuals exhibiting signs and symptoms of gastroenteritis.
Pathogens Detected by the GI Bacterial assay include:
5. Yersinia enterocolitica
6. Vibrio (V. parahaemolyticus, V. vulnificus, V. cholerae
7. E. coli O157
8. Plesiomonas shigelloides
GI Bacterial Panel with Reflex to GI Extended Panel, PCR Panther must be order seperately.
Note: If a GI Bacterial Panel PCR testing performed prior (≤3days), put in an additional test ordered and contact the Molecular department to add on the GI Extended Panel.
This assay is a multiplex real-time PCR intended to aid the differential diagnosis of individuals exhibiting signs and symptoms of gastroenteritis.
Pathogens Detected by the GI Bacterial assay include:
- Salmonella
- Shigella/Enteroinvasive E.coli (EIEC)
- Campylobater(C.coli, C.jejuni)
- Shiga toxin
5. Yersinia enterocolitica
6. Vibrio (V. parahaemolyticus, V. vulnificus, V. cholerae
7. E. coli O157
8. Plesiomonas shigelloides
Test Code
LAB1230659
CPT Codes
87505, 87506
Preferred Specimen
Liquid stool transferred into Cary-Blair transport medium to the proper fill line. Carey blair – Orange (Para-Pak C& S) or Green (Cary Blair w/ indicator) lids


Minimum Volume
3mL
Instructions
Liquid stool transferred into Cary-Blair transport medium to proper fill line. Transport at refrigerated temperature. Stable for 3 days
Transport Temperature
Refrigerated(2-8°C)
Specimen Stability
Refrigerated(2-8°C): 3 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Non-validated sample types.
Improper storage
Improper storage
Methodology
Qualitative Multi-plex Real time PCR performed on the Hologic Panther Fusion.
Setup Schedule
Monday-Friday
Reference Range
Negative
Clinical Significance
The results of this assay should be used in conjunction with clinical presentation, laboratory findings, and epidemiological information, and should not be used as the sole basis for diagnosis, treatment, or other patient management decisions.
Performing Laboratory
West Virginia University Hospital, Inc

