Magnesium

Test Code
LAB103


Alias/See Also
Mg


CPT Codes
83735

Preferred Specimen
4.5 ml (600 ul min) lithium heparin (green); alternate-SST (gold) or Red (no additive)


Minimum Volume
1 ml (200 ul minimum) plasma; alternate-serum


Other Acceptable Specimens
Gold SST


Instructions
After centrifugation, if not in gel barrier tube, pour off plasma or serum into an aliquot tube.


Transport Temperature
Room Temp.


Specimen Stability
Separated from cells: 24 hours room temp, 7 days refrigerated


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Icteric: >36 mg/dL bilirubin, Hemolysis: >150mg/dL, Lipemia: >500 mg/dL


Methodology
Colorimetric Endpoint

Setup Schedule
Mon- Sun


Reference Range
Plasma/Serum Range = 1.6 – 2.6 mg/dL
24 Hour Urine Range = 72.9 – 121.5 mg/24 hours
Random Urine Range = No established normal range


Clinical Significance
Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low) and
hypermagnesemia (abnormally high).


Performing Laboratory
Piedmont Athens Regional



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.