Resources

Volatiles

Message
Lab only orderable


Test Code
#Volatiles


Quest Code
7240


CPT Codes
80320 (HCPCS: G0480)

Includes
Acetone, Ethyl Alcohol, Isopropyl Alcohol, Methyl Alcohol


Preferred Specimen
Whole blood - 1 unopened fluoride oxalate (gray-top) tube


Patient Preparation
Do not use alcohol solutions as a skin preparation for drawing specimens. Use non-alcohol solutions such as Betadine® or Zephiran®.

Minimum Volume
0.5 mL


Other Acceptable Specimens
Whole blood collected in EDTA (lavender-top) or sodium heparin (green-top) tubes • 5 mL serum collected in a red-top tube (no gel) or plasma collected in EDTA (lavender-top) or sodium heparin (green-top) tubes)


Instructions
Do not open. Keep specimen tightly capped. Prevent exposure to atmosphere.

Do not use alcohol solutions as skin preparation for drawing specimens. Use non-alcohol solutions such as Betadine® or Zephiran®.


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 14 days
Refrigerated: 14 days
Frozen: Unacceptable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Serum separator tube (SST®)


Methodology
Chromatography

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule

Set up: Daily; Report available: 2-3 days



Reference Range
Alcohol, Methyl None detected
Alcohol, Ethyl mg/dL None detected
Alcohol, Ethyl g/dL(%) None detected
Acetone None detected
Alcohol, Isopropyl None detected


Clinical Significance
The assay is used to determine concentration and potential toxicity of these substances.


Performing Laboratory
Quest Diagnostics Chantilly Nichols Institute
14225 Newbrook Dr.
Chantilly, VA 20151-2228



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.