T3, Reverse,LC/MS/MSM (T3R)

Test Code
LAB138

Quest Code
90963

CPT Codes
84482

Preferred Specimen
0.5 mL serum in gold top tube or plain red top tube

Minimum Volume
0.3 mL

Other Acceptable Specimens
Plasma collected in: Sodium heparin (green-top) tube or EDTA (lavender-top) tube

Instructions
Allow blood to clot at room temperature for 30 minutes. Centrifuge and separate the serum from cells immediately. Alternatively, collect blood in a gel barrier tube, allow to clot at room temperature, centrifuge and remove from gel within 24 hours.

Transport Container
Transport tube

Transport Temperature
Room temperature

Specimen Stability
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 30 days

Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Unseparated serum (>48 hours on clot) • Serum in Serum Separator Tube (SST®) not separated from the gel within 24 hours

Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Afternoon Monday-friday

Reference Range
8-25 ng/dL

Clinical Significance
3,3',5'-Triiodothyronine (reverse T3, rT3) is, along with 3,3,5'-Triiodothyronine (T3) a deiodinated metabolite of thyroxine (T4), the major secretory product of the thyroid gland and is secreted into the bloodstream. Unlike T3, however, rT3 is thought to be metabolically inert.
The process of 5'-monodeiodination that converts T4 to T3, and rT3 to diiodothyronine (DTT) is inhibited in a wide variety of conditions, collectively referred to as nonthyroidal illnesses (NTI) or the 'euthyroid sick' state. These conditions include fasting, malnutrition, poorly controlled diabetes mellitus, trauma, surgery, and systemic illness. Consequently, in patients with NTI the serum T3 level typically decreases, and the rT3 often, but not always, increases.

Performing Laboratory
Quest Diagnostics Nichols Institute-Chantilly VA
14225 Newbrook Drive
Chantilly, VA 20151-2228




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.