| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Isotretinoin, Serum/Plasma
Test Code26519X
Preferred Specimen
Red Top PROTECT FROM LIGHT

Minimum Volume
0.3 mL


Other Acceptable Specimens
Plasma collected in light protected: EDTA (lavender-top) tube or EDTA (pink-top) tube
Instructions
Promptly centrifuge and separate serum or plasma into a light protected plastic screw capped vial using approved guidelines.
Known interferences: Isotretinoin [LC-MS/MS]:9-cis, 13-cis-retinoic acid
Known interferences: Isotretinoin [LC-MS/MS]:9-cis, 13-cis-retinoic acid
Transport Temperature
Room temperature
Specimen Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen -20° C: 4 months
Frozen -70° C: 14 months
Refrigerated: 30 days
Frozen -20° C: 4 months
Frozen -70° C: 14 months
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Received not protected from light • Serum Separator Tube (SST®) • PST
Methodology
High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
Setup Schedule
Set up: As needed; Report available: 1 day
Reference Range
See Laboratory Report
Clinical Significance
Therapeutic Drug Monitoring