Bismuth, Urine

Test Code
13722


CPT Codes
83018<br><strong>This test code is for New York patient testing. For non-New York patient testing, see test code 6060.</strong>

Preferred Specimen
2 mL urine collected in an acid-washed or trace metal-free plastic container


Minimum Volume
0.4 mL


Instructions
Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection


Transport Container
Acid-washed or trace metal-free plastic container


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen: 30 days


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.

Setup Schedule
Set up: Varies; Report available: 5 days


Reference Range
< 3 mcg/L




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.