A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
HE4, Ovarian Cancer Monitoring
Test Code16500
Alias/See Also
LAB373736
CPT Codes
86305
Preferred Specimen
0.5 mL serum
Minimum Volume
0.3 mL
Other Acceptable Specimens
SST
Instructions
Sample collected in a red-top tube must be allowed to clot for at least 30 minutes but no longer than 1 hour
Transport Container
Transport tube
Transport Temperature
Frozen
Specimen Stability
Room temperature: 48 hours
Refrigerated: 72 hours
Frozen: 28 days
Refrigerated: 72 hours
Frozen: 28 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • Lipemia • Icteric specimens • Presence of fibrin, RBCs or other particulate matter • Obvious microbial contamination
Methodology
Chemiluminescent Microparticle Immunoassay (CMIA)
Setup Schedule
Mon, wed, fri
Report Available
2-5 days
Limitations
A clinical study indicated that serial HE4 levels correlated with clinical status (progression vs. no progression) in 70% (247/354) of the study participants.
Reference Range
Female Premenopausal | ≤70 pmol/L |
Female Postmenopausal | ≤140 pmol/L |
Clinical Significance
The percentage increase in HE4 values has been used as an aid in monitoring recurrence or progressive disease in patients with invasive epithelial ovarian cancer. Currently there is no clinically accepted cut-off for use in monitoring cancer progression in epithelial ovarian cancer subjects with this assay. Serial testing for patient HE4 assay values should be used in conjunction with methods used for monitoring ovarian cancer.
Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA |
33608 Ortega Highway |
San Juan Capistrano, CA 92675-2042 |