Everolimus, Blood

Test Code
18883


Alias/See Also
LAB00482


CPT Codes
80169

Preferred Specimen
2 mL whole blood collected in an EDTA (lavender-top) tube


Minimum Volume
1 mL


Instructions
Drug regimens are to be noted on requisition: Time and date of drug administration.
Therapeutic range applies to trough specimens drawn just prior to a.m. dose.


Transport Container
EDTA (lavender-top) tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 7 days
Refrigerated: 14 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gel barrier tubes • Clotted specimens


Methodology
Chromatography/Mass Spectrometry

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
8: 00 a. M. Mon-sat


Report Available
1-3 days


Reference Range
Trough 3.0-8.0 ng/mL for Transplantation
Trough 5.0-10.0 ng/mL for Oncology/Neurology
Symptoms of toxicity are more likely to occur at trough levels exceeding 12.0 ng/mL


Performing Laboratory
Quest Diagnostics Nichols Institute
27027 Tourney Road
Valencia, CA 91355-5386




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.