Amikacin

Test Code
236


Alias/See Also
LAB2316
 


CPT Codes
80150

Preferred Specimen
1 mL serum collected in a red-top tube (no gel)


Patient Preparation
Collect trough just prior to next dose. Collect peak at end of 60 minute IV infusion or 30 minutes after end of 30 minute IV infusion or 60 minutes after IM dose.

Minimum Volume
0.2 mL


Other Acceptable Specimens
Plasma collected in: Fluoride oxalate (gray-top) tube or EDTA (lavender-top) tube


Transport Container
Transport tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 7 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Serum separator tube (SST) • Heparin plasma


Methodology
Immunoassay (IA)

Setup Schedule
Mon-sat


Reference Range
Amikacin, Peak 20.0-30.0 mg/L
Amikacin, Trough 4.0-8.0 mg/L


Clinical Significance
Amikacin is an aminoglycoside antibiotic used in the treatment of gram-negative bacillary infections. Amikacin is potentially nephrotoxic and ototoxic and serial monitoring of peak and trough serum levels provides information to maintain safe and therapeutic levels.


Performing Laboratory
Quest Diagnostics Nichols Institute-Chantilly VA
14225 Newbrook Drive
Chantilly, VA 20151-2228




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.