Diphtheria and Tetanus Antitoxoids

Test Code
34042


Alias/See Also
LAB792
TETANUS
DIPHT
DIPHTHERIA ANTIBODY PANEL


CPT Codes
86648, 86774

Preferred Specimen
2 mL serum collected in each of two separate tubes


Minimum Volume
0.3 mL


Transport Container
Transport tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 7 days
Refrigerated: 14 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • Grossly lipemic • Grossly icteric


Methodology
Immunoassay (IA)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Reference Range
Diphtheria Antitoxoid ≥0.10 IU/mL
Tetanus Antitoxoid ≥0.10 IU/mL


Clinical Significance
Used to evaluate diphtheria immunization response. Antibody levels of > or = to 0.10 IU/mL are considered protective. For Pre and Post vaccination testing to assess normal immune response, please refer to Test Code 10680, Diphtheria Antitoxoid, Pre and Post Vaccination.

Tetanus is caused by Clostridium tetani. Immunization with Tetanus Antitoxoid is effective with boosters in immunocompetent individuals. Antibody levels of > or = to 0.10 IU/mL are considered protective. However, tetanus can still occur in some individuals with such antibody levels. These results should not be used to determine the necessity to administer antitoxin when clinically indicated. For Pre and Post vaccination testing to assess normal immune response, please refer to Test Code 91424, Tetanus Antitoxoid, Pre and Post Vaccination.


Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.